Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Nuclear Medicine and Molecular Imaging ; (6): 559-563, 2017.
Article in Chinese | WPRIM | ID: wpr-607167

ABSTRACT

Objective To compare treatment response according to the PERCIST1.0,RECIST1.1,EORTC,and WHO criteria in patients with colorectal liver metastases (CLM) who received neoadjuvant chemotherapy.Methods A total of 41 CLM patients (27 males,average age 68.48 years;14 females,average age 62.43 years) from January 2010 to September 2013 were included in this retrospective study.PET/CT scan was performed before chemotherapy and after 4-6 cycles′ chemotherapy.The baseline and the sequential follow-up 18F-FDG PET/CT of each patient were evaluated according to the PERCIST1.0,RECIST1.1,EORTC,and WHO criteria.The response was categorized into 4 levels including CR,PR,SD,PD.PET/CT images were used for both metabolic and anatomic evaluation.The concurrent diagnostic CT or MRI images (performed within 1 week of PET/CT) were also utilized when needed.The agreements of criteria were analyzed using Kappa test.The response rate (RR) and disease control rate (DCR) were compared using χ2 test.Results The RR and DCR according to the PERCIST1.0,EORTC and RECIST1.1 criteria were 31.71%(13/41) and 63.41%(26/41),31.71%(13/41) and 60.98%(25/41),17.07%(7/41) and 68.29%(28/41),respectively.The general comparison of PERCIST1.0 and RECIST1.1,EORTC and RECIST1.1 criteria showed good agreements (κ values: 0.711,0.689).Significant difference was not found in the DCR(χ2=2.000,P>0.05) but found in the RR(χ2=6.000,P0.05),while the RR had significant difference(χ2=6.000,P0.05) but found in the RR(χ2=8.000,P<0.05) between PERCIST1.0 and WHO criteria.Conclusions In evaluating CLM treatment response,anatomical criteria and metabolic criteria have a good consistency.But metabolic criteria are more sensitive for RR evaluating.

2.
Journal of Interventional Radiology ; (12)1994.
Article in Chinese | WPRIM | ID: wpr-570618

ABSTRACT

Objective To evaluate the diagnostic value of CT guided percutaneous transthoracic core needle biopsy (TCNB). Methods CT guided TCNB were performed on 121 cases who had suffered from pulmonary diseases. Cook QC 18G, 19G, or 20 gauge needles were used. The diameter of the pulmonary lesions was ranged from 0.8cm to 9.5cm, mean (3.4?1.9)cm. Postbiopsy complications were observed by routine CT scan. Results According to the Westcott's method, the final diagnosis of 86 cases of malignancy and 35 cases of benignancy had been established. Seventy nine malignant and 32 benign ones could be accurately diagnosed by TCNB. The overall diagnostic accuracy was 91.7%(111/121). The sensitivity of TCNB in the malignancy was 91.9%(79/86) with 7 cases of false negative, and the specificity was 100%. Seventy cases of malignancy could be made definitely. The sensitivity of benignancy was 91.4%(32/35). Complication of pneumothorax in 22 cases (18.2%) and pulmonary hemorrhage in 19 cases (15.7%) resolving spontaneously. Conclusions CT guided TCNB is a safe, reliable method with high accuracy in diagnosis and less complications, especially for non lung cancer malignancy and benign lesions.

SELECTION OF CITATIONS
SEARCH DETAIL